Detroit 60 series starting problems.

Using a hook-end pick (J-39227) , reach into the thrust plate bore in the gear case, hook the perimeter seal, and pull it off of the thrust plate. Pass the seal between the thrust plate and camshaft and discard. Pull the diamond seal from the thrust plate groove and discard. Section 1.27.2.1. Inspection of Thrust Plate Perimeter Seal Groove.

Detroit 60 series starting problems. Things To Know About Detroit 60 series starting problems.

Detroit's electronically controlled Series 60 diesel engine was introduced during the first quarter of 1987. What was unique about this mill was that it was the brand's first ever clean-sheet design.Blog / Detroit Series 60: Life Expectancy and Common Problems. Dmitry Sapko, auto mechanic and car expert. September 18, 2023 | 15:00 👁 645. The Detroit 60 …Hi. My 06 Freightliner Coronado has a 500+ HP Series 60 Detroit and I having some issues with it I hope you may be able to help me with. Tends to idle rough when first starting when its cold even though its plugged in. Smoothens out after a minute or two depending how cold and we are talking a lot of -20 and colder mornings this past winter.#1 · Dec 29, 2011. Truck worked yesterday and parked, failed to start this morning. Throwing code 42- SRS sensor. Checked sensor and wiring ok. Checked Timing sensor …1. Connect Detroit Diesel Diagnostic Link (DDDL 7.0) to check the oil pressure. 2. Start and vary engine speed between 1800 - 2100 rpm. 3. Check DDDL 7.0 for oil pressure reading. [a] If DDDL 7.0 indicates oil pressure greater than or equal 241 kPa (35 psi) at 1800 rpm, shut down the engine and disconnect DDDL 7.0. Refer to section 6 to diagnose

Only from Detroit. The most successful Detroit Diesel engine ever produced, the Series 60 was also the first engine in the world to fully utilize electronic engine controls. With more than 1.2 million units sold since 1987, the Series 60 was the most widely used heavy-duty truck engine in North America by 1992.Series 60 - DDEC I; Series 40E Troubleshooting - Section 3.1 Injection Control Pressure System Operation; Series 60 - DDEC® V ELECTRONIC CONTROL UNIT - SERIES 60 2004; Series 60 - Fuel Lines; Series 60 - Section 2.49 Low Pressure Fuel Regulator for the Series 60G Engine; Series 60 - Section 2.50 Fuel Mixer for the Series 60G Low ...

Posted on May 04, 2017. Boost is produced by adding extra fuel in the combustion process to create a hotter exhaust and more exhaust gas pressure. boost is produced as the exhaust turbine winds up from that extra heat / pressure produced from the extra fuel. loose intercooler hoses , cracked intercooler will loose that extra boost.

I have 1999 freightliner century c120 DD engine series 60 I had the warning low oil pressure come on took it to the mechanic he said the oil pump is fine and the pressure is good the gauge shows good pressure from 45-50 psi at first when I start the truck the warning would come on and when the water temp reached 150 degrees and I …Learn how to fix the ECM problem on your Detroit 60 Series engine with this semi mechanical tutorial video.Series 60 – Section 8.5 DDEC V Varible Pressure Output Device; Series 60 – Section 8.6 DDEC IV Varible Pressure Output Devices; Series 60 – Section 8.3 Delivery Pipe; Series 60 – Section 8.4 EGR Rate Measurement System; Series 60 – Section 8.1 Tube and Shell Bolted Flange EGR Cooler; Series 60 – Section 8.2 …Warranty. Every new Series 60 engine is covered by the following standard warranty: Engine: 2 years, unlimited miles, including 100% parts and labor. Accessories (if supplied by Detroit): 2 years, 100,000 miles, including 100% parts and labor. Major components: 5 years, 500,000 miles, including parts and 100% of Service outlet's normal charge.

I have an 2001 Freightliner 60 series Detroit diesel 460 HP. When I start the truck when the engine is cold I am getting huge cloud ... 2006 FREIGHTLINER, DETROIT DIESEL SERIES 60 ENGINE, COOLANT CONSUMPTION PROBLEM. NO EXTERNAL WATER LEAKS. ENGINE RUNS PROPERLY. NO PRESSURE BUILD UP IN COOLING SYSTEM.

14. 8. Jun 12, 2015. 0. I have a 2004 Series 60 Detroit that has a serious problem with cranking and cranking and cranking until it juuuusssst finally starts. I have heard that check valves can be an issue on the Detroit so I replaced the check valve behind the engine and also the one that is inline on the right side of the filter housing.

Jan 5, 2016 · Having problem starting Detroit 60 series 12.7l engine, head gasket was replaced. I had wayne from here assist me earlier. I have narrow it down to the injector not getting a signal. I the ecm check b … read more 1 Oct 2018 ... Comments8 ; Troubleshooting a hard starting series 60. Prairie Mechanic · 20K views ; The click no start problem explained. (Updated). xMech · 143K&nbs...Series 60 Fuel Pump Starting Difficulty. To determine if the fuel pump is causing starting difficulty, perform the following steps: ‪. 1. Insert a piece of wire through the pump flange drain hole. 2. Crank the engine momentarily and feel for wire vibration. If the wire did not vibrate, determine if the drive hub or coupling should be replaced.The most successful Detroit Diesel engine ever produced, the Series 60 was also the first engine in the world to fully utilize electronic engine controls. With more than 1.2 million units sold since 1987, the Series 60 was the most widely used heavy-duty truck engine in North America by 1992. It has been used extensively in trucks, boats, power ...2005 columbia with 14l series 60. this engine has had an inframe done with new head and injectors. the truck starts and runs fine , but if it sits for 3 days it wont start unless you crank it for at least 2 minutes. it is like it ran out of fuel , no smoke out of the exhaust for the first minute, then starts puffing white smoke and finally starts. i have replaced the check valve …I have a 97 FLD 120 with a series 60 engine. As soon as I start the truck the fan comes on and stays on, cant seem to figure out what might be causing it. just replaced the bearing in the fan clutch. i check for an air leak. please help....Step 1. Locate the primer bulb on top of the primary fuel filter housing, located on the right-hand side of the engine. Press the primer bulb in and out with your hand and a clean rag until the bulb will no longer push in. This means the fuel filters are full of diesel.

Ive got a 60 series Detroit it's been running like shit. It's lacking in power, it will randomly start missing and - Answered by a verified Technician ... 1998 Freightliner series 60 Detroit multiple fuel related problems after sitting for periods of time when engine is first started sounds like it's running on one cylinder very very rough ...I had similar problem with my truck(05 Columbia/Detroit engine/10 speed) . The jake breaks would work intermittently. The first time it was in the repair shop the guy replaced Micro switch and relay. But It turned out to be the engine oil sensor. The repair shop replaced it with a new one and jake break works fine now. Hope it helps.Series 60 - Low Power - INCORRECT CAMSHAFT TIMING. Check the camshaft timing; if the dial indicator reading is within 0.262 - 0.284 in. (6.655 - 7.214 mm), no further troubleshooting is required. If the dial indicator reading is not within 0.262 - 0.284 in. (6.655 - 7.214 mm), check engine timing; refer to section 12.11.1.Truck Maintenance - help with fuel problem detroit 60 series 1995 - I have a detriot 60 series engine that took me 40 seconds to start once i started it I drove it for 15 minutes then I cutt it off and it would crank. I put 2 used fuel pumps on oday and none of them worked. i took the lines off the fuel pump to see ifSeries 60 Fuel Filter. Two spin-on type filters are used on the Series 60 engine. The first in the fuel flow is a strainer, and the second is a filter. Although they are not marked as such, the threaded sleeves that accept the cartridges are different sizes to prevent mismatching. The primary filter has a 1 in. x 12 thread. The secondary filter ...

The Detroit Diesel 60 Fault Codes guide is an essential resource for anyone working with these engine models. It empowers technicians, mechanics, and fleet managers with the knowledge and instructions necessary to diagnose, troubleshoot, and resolve issues related to the Series 60 engine, ensuring optimal performance and reliability. Language: RU.

1. 1. 1. 1. ATTENTION. The information in this document is accurate as of April 2004 and is subject to change without notice. This manual is to be used in conjunction with the DDEC III/IV Single ECM Troubleshooting Guide and the DDEC V Single ECM Troubleshooting Guide. Series 60®, Detroit Diesel®, DDC®, DDEC® and the spinning arrows design ...1. Place the red lead of a voltmeter to the solenoid “BAT” terminal. 2. Place the black voltmeter lead to the starter ground terminal, 3. Engage the starter switch. 4. View the voltage reading on the meter. If the voltage is less than specification while cranking the engine, replacement is necessary;3600 S. Noah Dr. Saxonburg, Pa. 16056. PittsburghPower.com, 724-360-4080. Share. Back to News. Even though the Detroit Diesel Series 60 was discontinued in 2011, it’s still one of the most common engines for Class 8 trucks. Some may not know about the fascinating story behind these engines. At the onset of WWII General Motors created the GM ...I have a Freightliner Century with a Detroit 12.7 s60. Recently the truck has become very hard to start and has lost power specially when going up hills. I have checked and cleaned the check valve on the filter and also the check valve behind the cylinder head. But still the same difficulty in starting, I have to use starting fluid all the time.1993 60 series Detroit diesel will start and run for only 30 seconds then shuts down. I have replaced the coolent level sensor. Submitted: 12 years ago ... i'm looking for some help on a 60 series detroit diesel engine with an intermintent no start problem. have checked trs and srs sensors. changed 1 injector that was leaking replaced 3 ...Hey Guys. I have a Series 60 Detroit engine in an '06 Prevost motorcoach. A few weeks ago it started losing prime. My mechanic has replaced the check valve coming from the fuel tank, no help. Another Detroit shop checked computer and said Syncronous Run Sensor needed replacing, no help. ... The problem typically shows up as a hard starting ...View the ECM/ECU output functions and set them to particular values to support troubleshooting. This can be particularly useful when troubleshooting electrical problems. View engine and trip totals. View the status of a set of maintenance monitors. Section 19.5.1.3 Snapshots. To start a new snapshot, perform the following steps.‪Series 60 DDEC VI Troubleshooting – Section 4.13 Extended Crank Time; Series 60 DDEC VI Troubleshooting – Section 4.14 Crank No Start; Series 60 DDEC VI Troubleshooting – Section 4.12 Low Compression; Series 60 DDEC VI Troubleshooting – Section 4.11 Restrictive Air Filter; Series 60 DDEC VI Troubleshooting – Section 4.10 Aerated Fuel22 Jul 2022 ... Our How-To Series rolls on. The boys tackle crank no-start this week. It's something many of us diesel owners have experienced, ...The Series 60 debuted in 1987 for the North American class-8 market. Much of its development happened as a collaboration between Detroit Diesel and John Deere, for example, the ring system, the cylinder heads, and most notably the electronic engine control. In the end, the two companies kept manufacturing separately, but their efforts produced ...

Carefully remove carbon from the injector exterior in the area where the tip joins the nut, using a clean rag with clean diesel fuel. Section 2.5.3. Disassembly of N3 Electronic Unit Injector. On a Series 60 engine that uses the N3 EUI, only the injector seal rings and injector washer are serviceable.

Information for Series 60 Engines,” available from authorized Detroit Diesel service outlets. Keep this Operator's Guide with the engine installation at all times. It contains important operating, maintenance, and safety instructions. Trademark Information DDC®, Detroit Diesel®, DDEC®, Series 60®, Optimized Idle®, Diagnostic Link ...

DDEC IV Boost Sensor Problem Discussion in 'Freightliner Forum' started by froze, Sep 12, 2013. Sep 12, 2013 #1. froze ... froze Bobtail Member. 2 0. Sep 12, 2013 0. Truck is an '02 Columbia with a 12.7 60 series Detroit pre egr. Had ecm replaced with a used one after Detroit programmed it it was throwing flash code #34 for low turbo boost ...Cold starts, aptly named for starting your engine in cold temperatures, have given Series 60 engines trouble. They can lose their prime and not start properly. Using a starting fluid should help combat this issue, and you shouldn’t have any other problems from it once the engine is running.amishdonkeys Discussion starter. 247 posts · Joined 2009. #1 · Oct 9, 2011. Have a 1995 379 Pete w/ a 12.7L 60 series detroit. Jake brake and cruise control doesn't work. There is power to dash switchs for jake and cruise. Power to the clutch sensor. Clutch sensor was tested and checked out OK.Series 60 DDEC IV white smoke and backfiring. I'm working on a HK model series 60 engine and it has a strange problem. At idle if you snap the throttle it misses and starts blowing white smoke. It runs fine going down the road till you get to last 2 gears and it will smoke and backfire when the throttle is released to shift gears.Oct 4, 2020 · There are three basic checks that should be performed: Check for active/historic codes. All causes need to be checked once the fault is identified. Record faults on the Application For Adjustment (AFA) claim, if there is to be a claim. Check the DDEC parameters, progressive shift settings, torque limiting values, and injector. codes. Feb 23, 2021. 0. Hi first post need so help, got a 1997 Peterbilt 379 Detroit 60 12.7 that will crank but won't start. to start my truck was running then one day it wouldn't start any more, I've changed the TRS and SRS sensors 4 months ago got 4 new batteries new positive cables starter to battery box, new ECM (battery was busted) new fuel pump ...Jun 21, 2011 · I have a Freightliner Century with a Detroit 12.7 s60. Recently the truck has become very hard to start and has lost power specially when going up hills. I have checked and cleaned the check valve on the filter and also the check valve behind the cylinder head. But still the same difficulty in starting, I have to use starting fluid all the time. There could be a couple things that can cause this. -SRS sensor malfunctioning. -TRS sensor malfunctioning. -ECM malfunctioning. -Bull gear bearing issue. There are only 2 sensors that will keep the truck from starting. The srs or trs sensor. The srs is used for cranking and the trs is for timing. I would inspect both sensors.Detroit Series 60 problems. Tags detroit series 60. Jump to Latest Follow ... Tends to idle rough when first starting when its cold even though its plugged in. Smoothens out after a minute or two depending how cold and we are talking a lot of -20 and colder mornings this past winter. Idles fairly fast, around 900 to 1000 rpms until its …Jul 19, 2021 · Yes, it can be difficult to cold start Detroit diesel series 60. One way to solve this issue is to regularly change the SRS and TRS sensors. However, keep in mind that both sensors should be replaced at the same time. It is also recommended to periodically maintain the cooling system to solve this issue.

Problem solved. Happy trucker. Well i hope this helps even just one person. If it does it was worth it. If any one has any input for me that i may need correcting please email me. ALways like to hear of better ways. ... 60 series Detroit Diesel won't start - tommyw-5088: 1/24/2010 18:57. Re: 60 series Detroit Diesel won't start - milofarmer1: 1 ...60 series Detroit. By bkorth January 11, 2022 in General Chat. Start new topic; Recommended Posts. bkorth. Posted January 11, 2022. bkorth. Members; 863 ... I've had good luck with interstate mcbee done several series 60 overhauls with them and no problems. Link to comment Share on other sites. More sharing options...The truck is a 2008 Freightliner Colombia with a Detroit 60 series with 630k miles. The problem I am having with the truck is: 1. wont perform auto regen. 2: will not finish a park regen. I took the truck to a well known independent Detroit mechanic which was referred by couple of drivers in the area.Problem solved. Happy trucker. Well i hope this helps even just one person. If it does it was worth it. If any one has any input for me that i may need correcting please email me. ALways like to hear of better ways. ... 60 series Detroit Diesel won't start - tommyw-5088: 1/24/2010 18:57. Re: 60 series Detroit Diesel won't start - milofarmer1: 1 ...Instagram:https://instagram. how to disable anti theft on ford fusionlexington ky wreckwordscapes level 1259gcu resources and writing expectations worksheet Series 60 can be programmed several ways on the 'idle shutdown. First of all of course it can be turned off. Then there is the shutdown like you said programmable from 2 minutes to a total of 99. Next is the idle shutdown set and a 'disable feature' allowed. This is set via either the scan tool or a laptop.15 Jan 2024 ... Comments13 ; Cold Start on Detroit diesel 60 series compilation. Life with Big E · 9.3K views ; Kenworth W900 C15 Cat Main Bearing Issues · New .... airport cinemahow many crips and bloods are there Technician: ClaytonH729. ok. YOu have 2 connectors on the injector harness. 1 injector controls cylidners 1,2,3 and the other connector controls 4,5,6. I will upload an engine wiring diagram that gives you pinouts. You will probably need to remove the terminals off each injector on cylinders 1,2, and 3, then look at the wiring diagram and check ...12.7 Detroit Rod and Main Bearings Torque Specs SPN 158 FMI 2: ECM Voltage Too Low MBE 900/4000 PID 110 - Coolant Temperature Above Recommended Normal Operating Range broward south regional courthouse Starting problems 60 series Detroit Discussion in 'Freightliner Forum' started by Texasshorty, Jan 14, 2012. Page 1 of 2 1 2 Next > Jan 14, 2012 #1. Texasshorty Bobtail Member. 5 0. Jan 12, 2012 Menard Texas 0. I bought a 2004 Freightliner Centry with 14-l detroit Runs great starts fine when engine is turned off and restarted. If it sits over ...Series 60 - DDEC II; Series 60 - DDEC I; Series 40E Troubleshooting - Section 3.1 Injection Control Pressure System Operation; Series 60 - DDEC® V ELECTRONIC CONTROL UNIT - SERIES 60 2004; Series 60 - Fuel Lines; Series 60 - Section 2.49 Low Pressure Fuel Regulator for the Series 60G Engine